Brand Name :HERONG ELECTRIC
Model Number :HPSP0500
Certification :Laboratory Qualification Approved by CNAS
Place of Origin :CHINA
MOQ :1PC
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :55days
Packaging Details :Export packing
MPPT voltage range :500V~900V
Maximum DC voltage :1100V
Maximum branch current :160A
Rated grid frequency :50Hz / 60Hz
cooling method :forced air cooling
Protection class :IP20
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Performance characteristics:

  • Adapt to high altitude and low temperature environment
  • Designed with film capacitors
  • Super powerful background oscilloscope and fault recording function
  • MPPT has fast tracking speed, high precision and wide range
  • Advanced anti-islanding technology with active and passive dual detection
  • IGBT drive and cooling air duct design with patented technology
  • Standard computer debugging rack and 220V power socket, comprehensive humanized consideration
  • The DC side switch can control the tripping protection by software, with a high degree of automation and more sound protection
  • Intuitive and convenient touch screen operation interface, complete and rich network communication interface and monitoring system
  • AC soft-start and AC-DC dual power supply redundancy, can complete low-voltage ride-through without external UPS or auxiliary power
  • Strong adaptability to the power grid, strong ability to suppress power grid harmonics and three-phase unbalance, wide adjustment range of active and reactive power, and fully guarantee the quality of power generation

1100V Forced Air Cooling Grid Connected Inverter Centralized Photovoltaic

Technical parameters (500kW,630kW,800kW/DC1100V):

Modle HPSP0500 HPSP0630 HPSP0800-CC
DC side parameters MPPT voltage range 500V~900V

520V~900V

500V~900V

Maximum DC voltage 1100V
Standard number of branches that can be connected 6-way 12-way
Maximum branch current 160A
AC side parameters Rated output power

500kW

630kW

800kW

Maximum output power 550kW

693kW

840kW

Rated output current

902A

1137A

1010A

1320A

Maximum output current 993A

1250A

1111 1386A
Rated grid voltage

320V

320V

360V 350V
Allowable voltage range 256V~368V

256V~368V

288V~414V

315V~385V

Rated grid frequency

50Hz / 60Hz

Allowable frequency range

±3Hz

Current Total Harmonic Content (THD)

<3% (rated power)

DC current component <0.5% (rated output current)
Power factor 0.9 (inductive) ~ 0.9(capacitive) 0.95 (inductive) ~ 0.95(capacitive)
System parameters Maximum efficiency

99.02%

99.01%

99.03% 99.01%
Chinese efficiency

98.3%

98.3%

98.4%

98.50%

Standby self-consumption

<50W

Cooling method Forced air cooling
Protection class

IP20(Indoor)/IP50(Outdoor)

Working temperature

-40℃~+55℃

Storage ambient temperature

-40℃~+70℃

Allowable altitude ≤5000m
Allowable relative humidity

5%~95%

Low pressure crossing Meet zero voltage ride through
Communication Interface

RS485,Ethernet

Mechanical parameters Machine size (width*height*depth)

1000*2150*800mm / 1220*2300*870mm

Weight ≤1000kg